Description
Due to a problem in the Quartus® II software version 14.1, 15.0 and 15.1, you may observe a calibration failure when using the UniPHY DDR2 full-rate controller in Stratix® V.
The calibration failure occurs because of incorrect settings for the DQ and DQS enable signals in the generated programming file (.sof) which causes the DQ and DQS signals to not toggle properly when running on hardware.
Resolution
This issue will be fixed in a future version of Quartus Prime software. Alternatively, use a DDR2 half-rate controller.