Article ID: 000083774 Content Type: Troubleshooting Last Reviewed: 12/21/2018

Why does “aocl diagnose” return the "Not configured with OpenCL BSP" error after a reboot on the Intel® Programmable Acceleration Card (PAC) with Arria® 10 GX FPGA?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to the inherent architecture of the PAC OpenCL Board Support Package (BSP), the PAC may lose the OpenCL BSP configuration after a machine reboot and reinitialization of the OpenCL environment variables as specified in the OpenCL on Intel® Programmable Acceleration Card with Intel® Arria® 10 GX FPGA Quick Start User Guide, leading the “aocl diagnose” command to present an error similar to the following:

aocl diagnose: Running diagnose from <user_path>/opencl/opencl_bsp/linux64/libexec

aocl diagnose: failed 1 times. First error below:

Vendor: Intel Corp

handle is: -2

Phys Dev Name Status Information

pac_a10_ee00000Uninitialized Not configured with OpenCL BSP.

Resolution

Navigate to the folder within the PAC software installation where hello_world.aocx resides. Run “aocl program acl0 hello_world.aocx” to install the BSP and fix the issue. Please note that programming with a .aocx file built using the clBuildProgram command does not similarly install the BSP if it doesn’t exist. This is a limitation in the current software.

Related Products

This article applies to 2 products

Intel® Arria® 10 GX FPGA
Intel® PAC with Intel® Arria® 10 GX FPGA

1