Article ID: 000083701 Content Type: Troubleshooting Last Reviewed: 10/30/2015

The Quartus II software Pin Planner and PowerPlay Power Analyzer display inaccurate Arria 10 transceiver voltages

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

The Quartus II software version 15.0 does not support updated voltages for Arria 10 devices. The Quartus II Settings File (.qsf) XCVR_VCCR_VCCT_VOLTAGE uses the values from previous software releases. The Pin Report and PowerPlay Power Analyzer erroneously display the VCCR_GXB/VCCT_GXB settings as 1.0 V and 1.1 V, instead of 1.03 V and 1.11 V, respectively.

Resolution

There is no workaround. This issue will be fixed in a future software release.

Related Products

This article applies to 1 products

Intel® Arria® 10 FPGAs and SoC FPGAs