Article ID: 000083453 Content Type: Troubleshooting Last Reviewed: 02/13/2006

Can I configure an EPF6016A device with an EPF6016 configuration file?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description The EPF6016A and EPF6016 devices are not configuration-file compatible; you cannot configure an EPF6016A device with an EPF6016 configuration file, or vice versa. To migrate an EPF6016 design to the EPF6016A device, change the device assignment to the EPF6016A device and recompile it. Using the Smart Recompile option will let the Compiler skip over the Logic Synthesizer and Fitter, speeding the recompilation.

After recompilation, Altera recommends re-running timing analysis and simulation to verify correct design operation with the faster EPF6016A device.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1