Article ID: 000083184 Content Type: Troubleshooting Last Reviewed: 11/15/2011

Unconstraint Clock in Stratix V Designs with GXB Transceiver and Transceiver Reconfiguration Controller Megafunction

Environment

  • Quartus® II Subscription Edition
  • Ethernet
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    When you run a full timing analysis on a Stratix V design that contains a GXB transceiver block and a Transceiver Reconfiguration Controller megafunction, the TimeQuest timing analyzer reports an unconstraint clock. The timing report shows the following:

    alt_xcvr_arbiter:pif[0].pif_arb|grant[0] was determined to be a clk but was found wt/o an associated clock assignment

    This issue affects Stratix V designs that contain GXB transceiver block and Transceiver Reconfiguration Controller megafunction.

    Resolution

    No workaround.This issue will be fixed in a future version of the Triple-Speed Ethernet MegaCore function.

    Related Products

    This article applies to 1 products

    Stratix® V FPGAs