Article ID: 000083067 Content Type: Troubleshooting Last Reviewed: 12/15/2014

"Error: PowerPlay Power Analyzer (quartus_pow) cannot be run -- target family MAX 10 FPGA is not supported"

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

You cannot enable the PowerPlay Power Analyzer for the MAX® 10 device in the Quartus® II software release version 14.0 update 2. When compiling your design, the Quartus II software generates the following error:

Error: PowerPlay Power Analyzer (quartus_pow) cannot be run -- target family MAX 10 FPGA is not supported
Resolution

The PowerPlay Power Analyzer is not supported for the MAX® 10 device in the Quartus II software release version 14.0 update 2. You must remove the FLOW_ENABLE_POWER_ANALYZER setting from your project Quartus II Settings File (.qsf) file, or set the FLOW_ENABLE_POWER_ANALYZER value to OFF.

This issue will be fixed in a future release of the Quartus II software.

Related Products

This article applies to 1 products

MAX® II CPLDs

1