Article ID: 000082266 Content Type: Error Messages Last Reviewed: 03/11/2013

Error (184057): Fitter cannot read Memory Initialization File db/>filename<.mif

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® II software version 12.0 and earlier, you may see this error when compiling a design with imported Quartus II Exported Partion (.qxp) files. This error occurs when the software reads the Memory Initialization Files (.mif) for the RAMs or ROMs referenced in the .qxp. These .mif files are supposed to be in the db directory after importing the partition, but they are missing.

Resolution

To work around this problem, copy the missing .mif files into the db directory.

This problem is fixed beginning with the Quartus II software version 12.1.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1