Article ID: 000081609 Content Type: Troubleshooting Last Reviewed: 12/23/2014

Is there a known issue with performing a write_param instruction in the ALTREMOTE_UPDATE megafunction, if an EPCQ256 configuration device is selected?

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description Due to a problem in the Quartus® II software version 13.1, the ALTREMOTE_UPDATE megafunction will not latch user data correctly when executing a write_param instruction for all parameters except for Page Select. This may result in settings such as the AnF bit, watchdog timer value and watchdog enable not being set correctly. This issue only occurs if the selected configuration device is an EPCQ256.
Resolution This problem is fixed beginning with the Quartus II software version 14.0.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1