Article ID: 000080959 Content Type: Troubleshooting Last Reviewed: 02/22/2017

Why does the Quartus Prime software hang at "The Fitter is using Advanced Physical Optimization"?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime software Pro and Standard edition version 16.1 Update 2 and earlier, you may see the tool hangs at the fitter stage ending with a message "The Fitter is using Advanced Physical Optimization". This problem occurs if you have the maximum processors allowed set to auto.

Resolution

To work around this problem, change the auto processors to a value with:

Assignments -> settings -> Compilation process settings -> Maximum processors allowed = <a value where your computer can support>

This problem is scheduled to be fixed in a future release of the Quartus Prime software.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1