Article ID: 000080646 Content Type: Error Messages Last Reviewed: 04/19/2024

Warning (332060): Node: :csr_controller|csr_control_data_reg[0] was determined to be a clock but was found without an associated clock assignment.

Environment

    Intel® Quartus® Prime Pro Edition
    Intel® Quartus® Prime Standard Edition
    Serial Flash Controller II Intel® FPGA IP
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime Pro and Standard Edition Software version 18.1 and earlier, you may see the register csr_control_data_reg [0] in the Serial Flash Controller II Intel® FPGA IP is reported as an unconstrainted clock.

Resolution

This warning can be safely ignored, csr_control_data_reg [0] is not a clock.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1