Article ID: 000080497 Content Type: Troubleshooting Last Reviewed: 07/22/2020

Why do the time bars not appear in the Signal Tap Logic Analyzer in the Intel® Quartus® Prime Pro and Standard Edition software when using a 4k resolution monitor?  

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Pro and Standard Edition software with the Windows* OS scaling resolution configuration, the time bars may not appear while using Signal Tap Logic Analyzer on 4k resolution monitors.

Resolution

 

To work around this problem in the Intel® Quartus® Prime Pro and Standard Edition software, change the monitor resolution to 1920 x 1080 and restart Windows* OS.

This problem is fixedstarting with the Intel® Quartus® Prime Pro Edition software version 21.1.