Timing-Related Warning Messages for DDR2 and DDR3 SDRAM Controller with UniPHY When Sharing PLLs on Stratix V Devices

Environment

    Quartus® II Subscription Edition
    PLL
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

When instantiating a design in PLL/DLL slave mode on a Stratix V device, the TimeQuest Timing Analyzer may display warning messages similar to the following:

Warning: Ignored filter at slave_report_timing_core.tcl(176): slave_inst0|controller_phy_inst|memphy_top_inst|umemphy|uio_pads| dq_ddio[1].ubidir_dq_dqs|altdq_dqs2_inst|thechain|clkin could not be matched with a keeper or register or port or pin or cell or net Warning: Command get_path failed
Resolution

This issue has no workaround. The warning messages can be safely ignored; however, do not rely on the accuracy of the resulting timing analysis.