Article ID: 000078523 Content Type: Error Messages Last Reviewed: 03/11/2013

Internal Error: Sub-system: CDB, File: /quartus/db/cdb/cdb_net_sys.cpp, Line: 3973

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description Due to a problem in the Quartus® II software version 12.0 SP1 and earlier, you may see this error if your design contains a tristate output pin if the Fitter packs the output enable register into an IO element and the data input of the tristate buffer is tied to a constant logic '1'.
Resolution

To avoid this problem, perform one of the following actions:

  • Use the Fast Output Enable Register assignment set to Off to prevent the Fitter from packing the output enable register into the IO element
  • Connect data input of the tristate buffer to a non-static signal

This problem is fixed beginning with the Quartus II software version 12.1.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1