No, remote update is only available for a single device AS configuration scheme because the master FPGA cannot assert nCONFIG signal if the reconfiguration is initiated from the core. In multi-device setup, all nCONFIG pins are wired together. Therefore, the slave device will not get reconfigured if the nCONFIG signals are not pulled low.