Description
In the TimeQuest timing analyzer, if the hold check is performed on the same physical clock edge then user-defined clock uncertainty applied with the
set_clock_uncertainty -hold is ignored.
Resolution
In the Quartus® II software version 11.1 SP1 and later, the set_clock_uncertainty constraint includes the option-enable_same_physical_edge that will force the TimeQuest timing analyzer to honor this hold uncertainty.