Article ID: 000077527 Content Type: Troubleshooting Last Reviewed: 08/23/2011

Mimic Path Incorrectly Placed

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT

Critical Issue

Description

The Quartus II software may fail to place the mimic path correctly. The report timing script then indicates a timing setup failure on the mimic path.

This issue affects all designs.

Your design may fail.

Resolution

Manually edit the following parameter in the auto-generated Synopsys design constraint (.sdc) script to correct the timing analysis:

mimic_shift

Add a value of at least the worst case failed slack to the value already stated in the Synopsis design constraint file.

This issue will be fixed in a future version of the DDR and DDR2 SDRAM Controllers with ALTMEMPHY IP.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1