Article ID: 000077361 Content Type: Error Messages Last Reviewed: 06/28/2017

Error (175001): The Fitter cannot place 1 HSSI_PMA_TX_CGB, which is within Arria 10 Transceiver Native PHY <INSTANCE>

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

You may see this error when using the Arria® 10 device, Native PHY IP in PIPE mode. This is error is due to a mismatch between bonding master setting and physical transceiver channel placement.  

Resolution

To fix this problem modify the bonding master setting in Native PHY IP to match transceiver channel placement. The bonding master should be in physical channel CH1 or CH4. For example, if the following x4 PIPE transceiver channel placement is used, the bonding master is 1.

Logical Channel
Physical Channel
Ch0GXBL1C_RX_CH3
Ch1GXBL1C_RX_CH4
Ch2GXBL1C_RX_CH5
Ch3GXBL1D_RX_CH0

 

Related Products

This article applies to 1 products

Intel® Arria® 10 FPGAs and SoC FPGAs

1