Article ID: 000076086 Content Type: Troubleshooting Last Reviewed: 11/18/2011

Cannot Launch MegaWizard Plug-In Manager by Opening Example Design for UniPHY External Memory Interfaces

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    You cannot reopen your project in the MegaWizard Plug-In Manager by clicking on your generated IP instantiation <working_dir>/<variation_name>_example_design/example_project/<variation_name>_example/<variation_name>_example.v

    or<working_dir>/<variation_name>_example_design/simulation/<variation_name>_example_sim/<variation_name>_example_sim.v

    Resolution

    To reopen your variation in the MegaWizard Plug-In Manager, follow these steps:

    1. In the Quartus II software, click MegaWizard Plug-In Manager on the Tools menu.
    2. Click Edit an existing custom megafunction variation and specify: <working_dir>/<variation_name>.v

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices