Article ID: 000075676 Content Type: Troubleshooting Last Reviewed: 04/19/2016

What length are supported in AXI fixed burst length in the Cyclone® V/Arria® V SoC Ethernet Media Access Controller?

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

The supported AXI fixed burst length in the Cyclone® V/Arria® V SoC Ethernet Media Access Controller when the AXI_Bus_Mode[0]: undefined register is  0x0 are from 4 to 16



The Cyclone® V/Arria® V Hard Processor System Technical Reference Manual version 15.1 and earlier incorrectly state 4-32.

Resolution

This problem will be fixed in future release of the Cyclone® V/Arria® V Hard Processor System Technical Reference Manual.

Related Products

This article applies to 1 products

Intel® Programmable Devices

1