Article ID: 000075355 Content Type: Troubleshooting Last Reviewed: 10/27/2017

Why does the Arria 10 HDMI Example Design intermittently fail read transfers after data rate switching above 5Gbps?

Environment

  • Intel® Quartus® Prime Pro Edition
  • HDMI Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    Due to a problem with the Intel® Arria® 10 HDMI design example, TX PMA recalibration fails to run after data rate switching. This can cause hardware failure for data rates >5Gbps

     

    Resolution

    This problem has been fixed starting in Intel Quartus® Prime version 17.0.2

    Related Products

    This article applies to 1 products