Article ID: 000074941 Content Type: Troubleshooting Last Reviewed: 11/05/2019

Can I set the Active Serial Clock source to CLKUSR when using Intel® Cyclone® 10 LP devices?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Cyclone® 10 LP Core Fabric and General Purpose I/Os Handbook, it is wrongly described that "Intel® Cyclone® 10 LP devices offer the option to select CLKUSR as the external clock source for DCLK" and this function can be set in the Intel® Quartus® Prime software in the Configuration tab of the Device and Pin Options dialog box.

    In fact, Intel Cyclone 10 LP devices don't support the usage of CLKUSR as the clock source for Active Serial (AS) configuration.

    Resolution

    This informaton is scheduled to be corrected in a future release of the Intel® Cyclone® 10 LP Core Fabric and General Purpose I/Os Handbook

    Related Products

    This article applies to 1 products

    Intel® Cyclone® 10 LP FPGA

    Disclaimer

    1

    All postings and use of the content on this site are subject to Intel.com Terms of Use.