Error (175005): Could not find a location with: OCT_CAL_BLOCK_ID of (value)

Environment

    Quartus® II Subscription Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

This error may occur when compiling a project which contains an LPDDR2 controller and one or more non-associated on-chip termination (OCT) blocks.

The reason is that the output only pins: CA[9:0], CKE, CK, CK_n and CS_n are not associated with a termination control block in the RTL code and they require an assignment to associate them with the termination control block within the LPDDR2 controller.

Resolution

Add a Termination Control Block assignment to the following output pins from the LPDDR2 controller:

CA, CKE, CK, CK_n, and CS_n

The value of the assignment should be made to the OCT control block within the LPDDR2 controller with the following hierarchy path: <variation name>|altera_mem_if_oct_cyclonev:oct0|sd1a_0

This issue is planned to be fixed in a future release of the Quartus® II software.