Article ID: 000074442 Content Type: Troubleshooting Last Reviewed: 12/21/2022

Why does Active Serial (AS) configuration from a Macronix MX25L device fail in Stratix® V, Arria® V, and Cyclone® V devices when using AS programming?

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel® Quartus® Prime Software version 18.1, Active Serial (AS) configuration from a Macronix MX25L device fails in Stratix® V, Arria® V, and Cyclone® V devices when programming the MX25L device using AS programming with a programmer object file (.pof) for AS x4 mode.

This is a known problem that is mentioned in the following knowledge article:

Why does the active serial (AS) configuration fail in Intel® Stratix® V, Intel® Arria® V, and Intel® Cyclone® V device when using a 256Mbit or larger density of Macronix MX25L or Cypress S25FL-S device for configuration device?

Although patch 0.05std for Intel Quartus Prime Standard Edition Software version 18.1 for the problem mentioned above is available from the following knowledge base article, it doesn't improve the problem when programming an MX25L device with a .pof for AS x4 mode:

Why do Cypress* flash devices S25FL256 and S25FL512 not get programmed with Intel® Quartus® Prime Standard edition software version 18.1 when using Intel® Cyclone® 10 LP or legacy devices?

Resolution

Program a Macronix MX25L device using JIC programming with a JTAG indirect configuration (.jic) file with Intel® Quartus® Prime Standard Edition Software version 18.1 with patch 0.05std.

This problem is fixed starting with the Intel® Quartus® Prime Standard Edition Software version 19.1.

Related Products

This article applies to 3 products

Stratix® V FPGAs
Cyclone® V FPGAs and SoC FPGAs
Arria® V FPGAs and SoC FPGAs