Article ID: 000074003 Content Type: Troubleshooting Last Reviewed: 12/12/2016

*** Fatal Error: Access Violation at 0X00007FFEA1CA07A4

Environment

    Intel® Quartus® Prime Pro Edition
BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Quartus® Prime software version 16.1 , you may see this internal error when archiving your design with the "File Set" options:

  • Service Request
  • Service Request with incremental compilation database
  • Compilation Database and output

 

*** Fatal Error: Access Violation at 0X00007FFEA1CA07A4

Module: quartus.exe
Stack Trace:
    0x207a3: HDB_NAMESPACE::set_compile_status 0x17 (DB_HDB)
    0x2019c: qtk_get_output_persona_filename 0xbc (db_qtk_tcl)

 

 

Resolution

To work around this problem, use the default archiver "File Set" setting of "Source control".

This problem is scheduled to be fixed in a future release of the Quartus Prime software.

Related Products

This article applies to 1 products

Intel® Programmable Devices