Why don't the IOPLL output clocks operate as expected when using Advanced Mode reconfiguration following table 18 in the Intel Agilex® 7 FPGA Clocking and PLL User Guide?

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Due to a problem in the Intel Agilex® 7 FPGA Clocking and PLL User Guide (UG-20216) version 2021.06.21, the address map for C1-C7 counters in table 18 is incorrect.

Therefore, if you follow the address map in table 18, the IOPLL output clocks will not output the correct clocks as expected.

 

 

Resolution

To work around this problem, follow the address setting and C Counter Mapping as shown in the following table.

Output Clock

C Counter

High Count

Low Count

Bypass Enable

Odd Divison

outclock0

C1

00011111

00100010

00100000

00100001

outclock1

C2

00100011

00100110

00100100

00100101

outclock2

C3

00100111

00101010

00101000

00101001

outclock3

C4

00101011

00101110

00101100

00101101

outclock4

C5

00101111

00110010

00110000

00110001

outclock5

C6

00110011

00110110

00110100

00110101

outclock6

C7

00110111

00111010

00111000

00111001

This problem is fixed starting with the release of the Intel Agilex® 7 FPGA Clocking and PLL User Guide version 2022.11.09.