Unexpected Sense Errors on Intel® Server System SR2500ALLX with the Intel® ROMB Card SROMBSAS18E

Documentation

Error Messages

000008028

02/25/2017

When operating an Intel® Server System SR2500ALLX or an Intel® Server Board S5000PAL with the Intel® ROMB card SROMBSAS18E, the following error message can at times be seen in the event log of the Intel® RAID Web Console 2 in a Windows* operating system:

Controller ID: 0 Unexpected sense: PD
= :14, CDB = 0x12 0x01 0x00 0x00 0xff 0x00 , Sense = 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00

These unexpected sense errors are harmless errors, where the Windows* operating system is making inquiries of the backplane that it cannot respond to. These errors can safely be ignored if all the sense data consists of zeros (0s) and do not affect the performance of the RAID array.