Reference Chassis List for Intel® Server Board S5000VSA

Documentation

Compatibility

000007945

01/13/2023

The reference chassis listed below includes the chassis that were tested to determine whether they provide adequate airflow to keep critical server components within the individual manufacturer's temperature specifications for Intel® Server Board S5000VSA.

 

Vendor Model Chassis Type Power Supply Thermal Test Level Drive Support EMC Note
AIC* RSC-2E-2 (RMC2E2-XP) 2U R/D 2 B    
AIC* RSC-3E-2 (RMC3E2-XP) 3U H/S 1 B    
Chenbro* SR107 FT -- 1 A, B    
Chenbro* SR108 FT -- 1 A, B    
Chenbro* SR205 FS -- 2 C    
Chenbro* SR105 MT -- 3 C    
Chenbro* SR106 MT -- 3 C    
Chenbro* SR101 MT -- 6 C    
Chenbro* RM21508B 2U -- 1 A, B    
Chenbro* RM31212B 3U -- 1 A, B   1
Chenbro* RM41416B 4U -- 1 A, B    
Chenbro* RM21600 2U -- 4 B    
Chenbro* RM23212 2U -- 6 A    
Chenbro* RM31616 3U -- 4 A    
Chenbro* RM31408 3U -- 4 A    
CiDesign* RS2108 2U -- 1 A, B    
CiDesign* RS2100 2U -- 2 A, B    

HEC* (Compucase)

S306 or
(RA364 US Only)
3U R/D 1 C    

HEC* (Compucase)

S411 or
(RA455 US Only)
4U H/S 1 C    
silentium* ActiveSilencer* Docking Station (ASDS) Accessory for SC5299-E N/A N/A N/A N/A 2

 

Notes
  1. This chassis was only tested and validated with 65nm Intel® Xeon® 5000 and 5300 Processor Series and 533MHz Fully Buffered DDR2 Memory Module.
  2. ActiveSilencer* Docking Station (ASDS) is only an optional accessory for SC5299-E chassis for noise reduction.

 

(1) Chassis Legend:

1U = Rack (U is multiple of 1.75 inches.)
2U = Rack (U is multiple of 1.75 inches.)
FT = Full Tower
FS = File Server
MT = Mid Tower

(2) Power Supply:
-- = Single
R/D = Redundant
H/S = Hot Swap Redundant

(3) Thermal Test Level:

Intel performs system level thermal testing of a given Intel Server Board in all listed 3rd party reference chassis. The server board is configured to use a generic fan control scheme that operates all attached system fans at 100% pulse width modulation (PWM). The generic fan control scheme is set by selecting the OTHER CHASSIS option using the FRUSDR Configuration Utility.

Intel cannot guarantee that specific system configurations will remain within maximum thermal limits if you choose to modify and reduce the fan control PWM rate from the tested configuration. If you choose to modify the fan control PWM rate, you are wholly responsible for all required thermal validation to ensure their system configurations stay within specified maximum thermal limits.

Refers to the highest level of testing that successfully completed Intel's thermal testing. The chassis configuration summary is provided below:

 

Level Board Revision Processor Maximum Speed Manufacturing Process Technology Number of Drives Ambient Temperature
1 All Intel® Xeon® Processor 5000 Sequence 3.2 GHz 65nm 2 35 Celsius
2 All Intel® Xeon® Processor 5000 Sequence 3.2 GHz 65nm 2 30 Celsius
3 All Intel® Xeon® Processor X5365 3 GHz 65nm 2 35 Celsius
4 All Intel® Xeon® Processor X5365 3 GHz 65nm 2 30 Celsius
5 All Intel® Xeon® Processor E5345 2.33 GHz 65nm 2 35 Celsius
6 All Intel® Xeon® Processor E5345 2.33 GHz 65nm 2 30 Celsius


(4) Drive support Option Legend:
 

Option Designator Supported Drive Type
A Docking SAS
B Docking SATA
C Cabled SAS/SATA

 

The testing information is provided as a guide for the reseller in choosing chassis products that are compatible with the Intel® Server Board S5000VSA. The reseller is encouraged to test the chassis products in specific configurations.

IMPORTANT INFORMATION AND DISCLAIMERS: The content of the website links located in the tested chassis list is not controlled by Intel. These links are being offered for your convenience and should not be viewed as an endorsement by Intel of the content, products, or services offered there. This listing is not intended to be all inclusive, nor is it an endorsement by Intel; it only represents chassis Intel has examined to date. Users of this list are reminded to check with the chassis manufacturer to get latest model specifications and ensure a particular chassis model is adequate for the user's intended purposes. This list is subject to change at any time. Check this website regularly for updates. For purposes of future server board introductions, Intel may test current and additional chassis, which may result in a revision of this chassis list. Intel reserves the right to modify this document at any time without notice. Intel assumes no responsibility for any errors which may appear in this document, nor does it make any commitment to update the information contained in it. Intel disclaims any liability or obligation for damages of any kind arising out of the application or use of the information contained in this document.

INTEL DISCLAIMS ALL WARRANTIES AND GUARANTEES, EXPRESS, IMPLIED OR OTHERWISE, ARISING FROM OR CONCERNING THE CONTENTS OF THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF ANY THIRD PARTY. INTEL MAKES NO CLAIMS OF COMPLIANCE WITH ANY GOVERNMENTAL REGULATORY AGENCY.

Intel does not convey any license, express, implied or statutory, by estoppel or otherwise, arising under its intellectual property rights, nor under the rights of others. This information is for reference use by PC integrators only. PC integrators are not authorized to refer to Intel's testing or reporting activities in advertising or any other manner.