Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: Intellectual Property


Last Modified: October 07, 2020
Version Found: v20.2
Version Fixed: v20.3
Bug ID: 14011318578
IP: Avalon-MM Stratix 10 Hard IP for PCI Express, Avalon-ST Stratix 10 Hard IP for PCI Express

Why does the system console tool in the Intel® Quartus® Prime Pro edition software version 20.2 reports several errors when loading a design that enables PCI* Link inspector and includes more than one instance of the Intel® Stratix® 10 Hard IP for PCI Express?

Description

Due to a problem in the Intel® Quartus® Prime Pro edition software version 20.2, you may see below errors when loading a design that enables PCI* Link inspector and includes more than one instance of the Intel® Stratix® 10 Hard IP for PCI* Express.

SEVERE: Failed to query if the PHY has PRBS soft logic

SEVERE: Failed to query the PHY's number of channels

SEVERE: Failed to query if the PHY has ODI soft logic

Workaround/Fix

This problem has been fixed starting with the Intel® Quartus® Prime Pro edition software version 20.3 and later.