Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: Tools


Last Modified: October 01, 2019
Version Found: v19.3
Bug ID: 1507429050

Why does the PHY Lite for Parallel Interfaces Intel® Stratix® 10 FPGA IP cannot be assigned to Bank 3A or 3D when using the Intel® Stratix® 10 1ST040*, 1SG040* and 1SX040* devices?

Description

Due to the limitation of the Intel® Stratix® 10 1ST040*, 1SG040* and 1SX040* devices, you will see hardware failure if you assign the PHY Lite for Parallel Interfaces Intel® Stratix® 10 FPGA IP to Bank 3A or 3D in the Intel® Quartus® Prime Pro Edition software version 19.3. 

Workaround/Fix

To avoid this problem, do not assign the PHY Lite for Parallel Interfaces Intel® Stratix® 10 FPGA IP to Bank 3A or 3D for Intel® Stratix® 10 1ST040*, 1SG040* and 1SX040* devices.