Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: Tools


Version Found: v18.1 Update 2
Version Fixed: v19.2
Bug ID: 1409255367 / 1409298174

Why a partial reconfiguration operation fails after a successful partial reconfiguration operation on the Intel® Stratix® 10 devices?

Description

Due to a problem in the Intel® Quartus® Prime Pro edition software version 18.1 Update 2 and 19.1, when performing partial reconfiguration operations, one after another, you may find occasional failures. The unsuccessful partial reconfiguration operations will assert the PR_ERROR signal.

Workaround/Fix

A patch is available to fix this problem for the Intel® Quartus® Prime Pro Edition software version 18.1 Update 2 and 19.1. Download and install Patch 2.06, 2.06p, 0.14fw or 0.14fwp from the appropriate link below.

Intel® Quartus® Prime Pro edition software version 18.1 Update 2


Intel® Quartus® Prime Pro edition Programmer and Tools version 18.1 Update 2


Intel® Quartus® Prime Pro edition software version 19.1


Intel® Quartus® Prime Pro edition Programmer and Tools version 19.1

 

This problem has been fixed starting with the Intel® Quartus® Prime Pro edition software version 19.2.