Due to a problem in the Intel® Quartus® Prime Pro Edition software version 19.1, you may see this internal error when compiling an Intel® Stratix® 10 design containing a PR (Partial Reconfiguration) region. This problem occurs when the static root partition has been migrated from an earlier backward compatible version.
Device Family: Intel® Stratix® 10
Intel Software: Quartus Prime Pro
Type: Answers
Area: Tools
Last Modified: Thu Apr 18 2019 06:04:00 GMT-0700
Version Found: v19.1
Bug ID: 1507043000
Internal Error: Sub-system: OCT, File: /quartus/periph/oct/oct_gen6.cpp, Line: 1079
Description
Workaround/Fix
To work around this problem, discard the original compiled static root partition and recompile it in the Intel® Quartus® Prime Pro Edition software version 18.1 Update 1 or later.
This internal error is scheduled to be replaced with a clear and helpful error message in a future release of the Intel® Quartus® Prime Pro Edition software.