Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: Tools


Last Modified: Mon Mar 11 2019 20:33:00 GMT-0700
Version Found: v18.1
Version Fixed: v18.1 Update 1
Bug ID: 00399655

Routing Error: Signal is constrained to be routed over global network but signal must be routed locally

Description

Due to a problem in the Intel® Quartus® Prime Pro Edition software versions 18.0 and 18.1, when compiling an Intel® Stratix® 10 Partial Reconfiguration design, you may encounter following routing error message:

xxxx (signal name) is constrained to be routed locally to destination(s), but signal must be routed globally An error has occurred while trying to initialize the plan stage.

Workaround/Fix

This problem has been fixed beginning with the Intel® Quartus® Prime Pro Edition software version 18.1 Update 1.