Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: Tools


Last Modified: August 03, 2018
Version Found: v18.0 Update 1
Bug ID: FB: 572284;

Why can't I generate a programming file for an Intel® Stratix® 10 110 ES device?

Description

Due to a problem in the Intel® Quartus® Prime Pro edition software version 18.0 Update 1, you cannot generate programming files for the following SX ES and GX ES devices.

GX :

1SG110HN1F43E2LGS1
1SG110HN1F43E2VGS1
1SG110HN2F43E2LGS1
1SG110HN2F43E2VGS1
1SG110HN3F43E2LGS1
1SG110HN3F43E2VGS1
1SG110HN3F43E3VGS1

SX:

1SX110HN1F43E2LGS1
1SX110HN1F43E2VGS1
1SX110HN2F43E2LGS1
1SX110HN2F43E2VGS1
1SX110HN3F43E2LGS1
1SX110HN3F43E2VGS1
1SX110HN3F43E3VGS1

Workaround/Fix

To work around this problem, download and install the patch 1.11 for version 18.0 Update 1 from the following links. You must install the Intel Quartus Prime Pro Edition software version 18.0 Update 1 before installing this patch.

You must enable the dev_password in the Readme file in order to generate the programming files.

This problem is scheduled to be fixed in a future release of the Intel Quartus Prime Pro Edition software.