Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime

Type: Answers

Area: Tools


Last Modified: December 05, 2018
Version Found: v18.0 Update 1
Bug ID: FB: 2205698443;

Internal Error: Sub-system: SCL, File: /quartus/synth/scl/scl_wysiwyg_atom_factory.cpp, Line: 9148

Description

Due to a problem in the Intel® Quartus® Prime software version 18.0, the compiler caused wrong file references in the database on Windows, and you may see the following critical warning in addition to the internal error:

Critical Warning (127003): Can't find Memory Initialization File or Hexadecimal (Intel-Format) File: <Intel Quartus Working Project>/recalibration.mif -- setting all initial values to 0 File: <Intel Quartus Working Project>/altera_syncram_impl_06l3.tdf Line: 35

Workaround/Fix

To work around this problem, copy the memory initialization file (.hex) into the Intel® Quartus® working project directory, similar to the location of the critical warning.

This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime software.