Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: Tools


Last Modified: June 20, 2018
Version Found: v18.0 Update 1
Bug ID: FB: 559674;
IP: Altera IOPLL

Error (20181) The permit_cal input of IOPLL is not connected correctly.

Description

In the Intel® Quartus® Prime Pro Edition software version 18.0 Update 1, you may see this error message when compiling an Intel Stratix® 10 design with cascaded PLLs. This error message is new in version 18.0 Update 1 and is the result of a new legality check to prevent downstream PLLs being calibrated when the upstream PLL has failed calibration.

Error (20181) The permit_cal input of IOPLL <downstream PLL> is not connected correctly. The permit_cal port of downstream IOPLL <downstream PLL> should be exported using the IOPLL IP Parameter Editor and connected to the locked output of upstream IOPLL <upstream PLL>

Workaround/Fix

To avoid this error, ensure that the downstream PLL's 'permit_cal' input port is exposed by checking 'Connect to an upstream PLL through Core Clock Network Cascading (create a permit_cal Input signal)' in the Parameter Editor GUI for the PLL and this port is connected to the locked port of the upstream PLL.