Article ID: 000076145 Content Type: Error Messages Last Reviewed: 08/23/2011

Error Message When Recompiling a Project

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    If you move the directory containing your Quartus II project, or rename your Quartus II project and recompile it without regenerating the DDR or DDR2 SDRAM Controller, you may receive the following error:

    Error: DDR timing cannot be verified until project has been successfully compiled.

    This error indicates that some of the settings files contain references to the previous location or project name and the verify timing script is unable to find the current project.

    This issue affects all configurations.

    The timing script does not verify your design.

    Resolution

    Regenerate your controller in IP Toolbench and recompile the project. The timing analysis script now completes correctly.

    This issue will not be fixed.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices