Critical Issue
If you set VCS as your simulator and attempt to simulate your high-performance controller II (HPC II)-based design with NativeLink, the VCS simulation fails and reports that the module was previously declared.
This issue affects all high-performance controller II (HPC II)-based IP designs with ALTMEMPHY.
Compilation fails in VCS.
The workaround for this issue is to perform the following steps, before running the simulation:
- Open the
<
variation_name>.v
file in an editor. - In the
<
variation_name>.v
file, find the following text:// IPFS_FILES: <files list>;
- Remove the entire file list by replacing the text located
in step 2 with the following text:
// IPFS_FILES: ;
This issue will be fixed in a future version.