Article ID: 000082697 Content Type: Troubleshooting Last Reviewed: 03/30/2023

Why do I get an error in the DDR3 with UniPHY memory controller when I uncheck the "Enable Reordering" check box under the Controller Settings tab?

Environment

  • Quartus® II Software
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    In the DDR3 memory controller with UniPHY version 11.0, if the Enable Reordering checkbox under the Controller Settings tab is not selected and the Starvation limit for each command is set to anything other than 10, then the following error message is displayed:

    Error: : The value for 'Starvation limit for each command' is only valid when 'Enable Reordering' checkbox is checked.

    Resolution

    The solution is to set the Starvation limit for each command to 10 then uncheck the Enable Reordering checkbox.

    This problem is fixed starting with the Quartus® II software version 12.1.

    Related Products

    This article applies to 1 products

    Stratix® V GX FPGA