Device Family: Arria® II GZ, Arria® V GT, Arria® V GX, Arria® V GZ, Arria® V ST, Arria® V SX, Cyclone® V E, Cyclone® V GT, Cyclone® V GX, Cyclone® V SE, Cyclone® V SX, Stratix® III, Stratix® IV E, Stratix® IV GT, Stratix® IV GX, Stratix® V E, Stratix® V GS, Stratix® V GT, Stratix® V GX

Type: Answers

Area: Component, EMIF


IP Product: RLDRAM II Memory Controller

How do you export the EMIF Toolkit full calibration and margin report in one file ?

Description

In the Quartus® II software version 12.1 and later, there is an issue with the EMIF Toolkit exporting the calibration report in a single file. It only allows exporting of each individual section of the report.

Workaround/Fix

The following workaround can be used to export the full calibration report :

After running the "Generate Margining Report" command, type the following tcl command in the EMIF toolkit console:

write_connection_target_report -id <id_value> -file "<report_name>"

where <id_value> is the Connection ID of the memory interface shown in the Connections Report -> Linked Connections.

An example command is :

write_connection_target_report -id 0 -file "report0.rpt"

This issue will be fixed in a  future version of the Quartus II software.