Type: Answers

Area: EMIF

Area: Intellectual Property


IP Product: RLDRAM II Controller with UniPHY

Why does the Report DDR section in TimeQuest only report 10 paths?

Description

By default, the UniPHY-based controller timing analysis in TimeQuest will report 10 paths. To increase the number of paths shown:

  1. Open <variation name>_p0_parameters.tcl in a text editor.
  2. Find set IP(num_report_paths) 10 in the text.
  3. Change the value to the number of paths you want to report.
  4. Re-run TimeQuest timing analysis.

Workaround/Fix