Type: Answers

Area: Embedded

Area: Tools



Error (10517): VHDL type mismatch error at altera_epcq_controller_core.vhd(17): boolean type does not match integer literal

Description

Due to a problem in the Quartus® II software version 14.1, you will receive this error when compiling a Qsys design which contains the Altera Serial Flash Controller, generated using VHDL.

Workaround/Fix

Use the Verilog language for Qsys generation.