Device Family: Arria® V GT, Arria® V GX, Arria® V GZ, Arria® V ST, Arria® V SX, Cyclone® V E, Cyclone® V SE, Cyclone® V ST, Cyclone® V SX, Stratix® III, Stratix® IV E, Stratix® IV GT, Stratix® IV GX, Stratix® V E, Stratix® V GS, Stratix® V GT, Stratix® V GX

Type: Answers

Area: EMIF, Intellectual Property


IP Product: DDR3 SDRAM Controller MegaCore supporting UniPHY

Error: Could not find a location with: OCT_CAL_BLOCK_ID

Description

When compiling a design with multiple UniPHY-based DDR2 or DDR3 memory controllers in the Quartus® II software version 12.1, you may experience the following error:

Error : Illegal constraint of pin to the region (X1, Y1) to (X2, Y2): no valid locations in region
    Info : The pin name: mem_ck

Info : The I/O pad is constrained to the location PIN_NUM due to: User Location Constraints (PIN_NUM)
    Error : Could not find a location with: OCT_CAL_BLOCK_ID of 2 (1 location affected)
        Info : pin containing PIN_NUM

The error is generated because the mem_ck pin is assigned to the wrong OCT termination control block.

Workaround/Fix

The workaround is to add the following termination control block assignment to the QSF file or Assignment Editor:

 

set_instance_assignment -name TERMINATION_CONTROL_BLOCK “<hierarchy>|altera_mem_if_oct_stratixv:oct0|sd1a_0" -to mem_ck*

 

This issue will be fixed in a future release of the Quartus II software.