Article ID: 000077919 Content Type: Troubleshooting Last Reviewed: 07/02/2012

XON Pause Frames are Sent when Receive FIFO Buffer is Congested

Environment

  • Quartus® II Subscription Edition
  • Ethernet
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    This errata affects the Triple-Speed Ethernet MegaCore function.

    The MAC function sends XON pause frame instead of XOFF pause frame when the receive FIFO buffer is almost full.

    This issue affects all designs with full-duplex flow control enabled.

    Resolution

    This issue has no workaround.This issue is fixed in version 11.1 SP2 of the Triple-Speed Ethernet MegaCore function.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices