VHDL Post-Fit Simulation Failure on Stratix V Devices

Description

This problem affects DDR2, DDR3, QDR II, and RLDRAM II products.

Error messages similar to the following may occur when running post-fit simulation of VHDL designs:

# ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(32614): (vcom-1136) Unknown identifier "test_mode". # ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(32615): (vcom-1136) Unknown identifier "use_duty_cycle_correction". # ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(71612): (vcom-1035) Formal port "clkin" has OPEN or no actual associated with it. # ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(183112): (vcom-1136) Unknown identifier "test_mode". # ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(183113): (vcom-1136) Unknown identifier "use_duty_cycle_correction". # ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(225095): (vcom-1136) Unknown identifier "test_mode". # ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(225096): (vcom-1136) Unknown identifier "use_duty_cycle_correction". # ** Error: /<project_path>/example_project/simulation/modelsim/myDDR3_example.vho(237040): VHDL Compiler exiting.

Workaround/Fix

The workaround for this issue is to modify the post-fit netlist, as follows:

  1. Open the post-fit netlist file <core_name>.vho in a text editor.
  2. Locate and remove the following parameter declaration for stratixv_leveling_delay_chain:
  3. test_mode => "false" use_duty_cycle_correction => "false"�
  4. Ground the clkin port of stratixv_pll_dll_output:
  5. clkin => "0000"
  6. Ground the tdoutap port of stratixv_jtag:
  7. tdoutap -> ‘0’