Device Family: Arria® V, Cyclone® IV

Type: Answers, Errata

Area: EMIF, Intellectual Property



RTL Modification Required for Top/Bottom Bonding on Arria V and Cyclone V Devices

Description

This problem affects DDR2 and DDR3 products.

For Arria V and Cyclone V devices, you must modify the resulting RTL code if you want to bond a hard interface on the top of the device with one on the bottom.

Workaround/Fix

The workaround for this issue is as follows:

The I/O pin pll_ref_clk cannot route to both the top and bottom PLLs; therefore it is necessary to route the I/O through the GCLK network and fanout to both PLLs.

Add the following lines to your RTL file:

wire global_pll_ref_clk; altclkctrl #( .clock_type("GLOBAL CLOCK"), .number_of_clocks(1) ) global_pll_ref_clk_inst ( .inclk(pll_ref_clk),.outclk(global_pll_ref_clk));

Replace the input signal pll_ref_clk in your hmi0 and hmi1 instantiations with global_pll_ref_clk.

This issue will be fixed in a future version.