Device Family: Intel® MAX® 10

Type: Answers

Type: Errata

Area: EMIF

Area: Tools



The Quartus II software verion 14.1 does not include DDR3 I/O placement rules for MAX 10 devices

Description

The Quartus II software release version 14.1 does not include some DDR3 I/O placement rules for external memory interfaces (EMIFs) and voltage references (VREFs) on MAX 10 devices. Without restrictions for placing general-purpose I/Os (GPIOs) near EMIF or VREF pins, the 10M08 and 10M50 devices can function incorrectly.

Workaround/Fix

This issue is fixed in the Quartus II software version 15.0. There is no workaround for previous software releases.