Article ID: 000080206 Content Type: Troubleshooting Last Reviewed: 03/24/2014

Memory Parameter Presets May Not Appear in Parameter Editor

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    This problem affects DDR2 and DDR3, LPDDR2, QDR II, and RLDRAM II products.

    When using the Quartus II software version 13.1, and targeting an Arria V, Cyclone V, or Stratix V device, the Presets list on the Memory Parameters tab of the parameter editor may be empty.

    Resolution

    The workaround for this issue is to open each of the following files in a text editor, and change each occurrence of 13.1.1 to 13.1 :

    /../.ip/altera/alt_mem_if_ddr2_emif/alt_mem_if_ddr2_mem_model.qprs /../.ip/altera/alt_mem_if_lpddr2_emif/alt_mem_if_lpddr2_mem_model.qprs /../.ip/altera/alt_mem_if_rldramii_emif/alt_mem_if_rldramii_mem_model.qprs /../.ip/altera/alt_mem_if_qdrii_emif/alt_mem_if_qdrii_mem_model.qprs /../.ip/altera/alt_mem_if_hps_emif/alt_mem_if_ddr3_mem_model.qprs /../.ip/altera/alt_mem_if_ddr3_emif/alt_mem_if_ddr3_mem_model.qprs /../.ip/altera/alt_mem_if_rldram3_emif/alt_mem_if_rldram3_mem_model.qprs

    For example, in the file /../.ip/altera/alt_mem_if_ddr3_emif/alt_mem_if_ddr3_mem_model.qprs, change:

    <ip><presets version="13.1.1"> <preset name="ELPIDA EDJ1108BASE-8C" kind="altera_mem_if_ddr3_emif" version="13.1.1" description="ELPIDA EDJ1108BASE-8C">

    to:

    <ip><presets version="13.1"> <preset name="ELPIDA EDJ1108BASE-8C" kind="altera_mem_if_ddr3_emif" version="13.1" description="ELPIDA EDJ1108BASE-8C">

    This issue is fixed in the Quartus II software version 13.1.2.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices