Article ID: 000079888 Content Type: Troubleshooting Last Reviewed: 06/30/2014

Transmit Path: CRC Insertion Must Be Turned On

Environment

  • Quartus® II Subscription Edition
  • Ethernet
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    For Low Latency Ethernet 10G MAC designs that turn on PTP 1-step clock support, you must enable CRC insertion. If you do not configure CRC insertion, you may get incorrect data frames when the pause frames and data frames interleave.

    This issue is fixed in version 14.0 of the Low Latency Ethernet 10G MAC.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices