Article ID: 000077637 Content Type: Troubleshooting Last Reviewed: 11/04/2013

IP Generation Fails When Both Efficiency Monitor and Ping Pong PHY Enabled

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    This problem affects DDR2, DDR3, LPDDR2, RLDRAM II and RLDRAM 3 products.

    IP generation fails when you attempt to instantiate your UniPHY-based external memory interface IP with both the Efficiency Monitor and Protocol Checker and Ping Pong PHY enabled.

    Resolution

    The workaround for this issue is as follows:

    1. In Qsys, manually instantiate your UniPHY-based external memory interface IP with Ping Pong PHY enabled and the Efficiency Monitor and Protocol Checker disabled.
    2. Instantiate two copies of the Efficiency Monitor and Protocol Checker and connect them to the avl_c0 and avl_c1 interfaces of the UniPHY IP.

    This issue will be fixed in a future version.

    Related Products

    This article applies to 1 products

    Intel® Programmable Devices