Device Family: Intel® Arria® 10, Intel® Cyclone® 10 GX, Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers

Area: DSP, Intellectual Property


Last Modified: September 09, 2020
Version Found: v20.1
Version Fixed: v20.2
Bug ID: 1508266278
IP: NCO

Why does the NCO Intel® FPGA IP fail to generate RTL when using the Intel® Quartus® Prime Pro edition software version 20.1?

Description

Due to a problem in the Intel® Quartus® Prime Pro Edition software version 20.1, you may see "Error: qsys-generate failed with exit code 1" when generating the NCO Intel® FPGA IP.

Workaround/Fix

No workaround to this problem exists in version 20.1 of the Intel® Quartus® Prime Pro  Edition software.

This problem has been fixed starting in the Intel® Quartus® Prime Pro  Edition software version 20.2.